Sustainable by design: Remodeling datacenter water effectivity

Be taught extra about how we’re making progress in direction of our sustainability commitments by way of the Sustainable by design weblog collection, beginning with Sustainable by design: Advancing the sustainability of AI.


Final month, we unveiled our Datacenter Neighborhood Pledge, emphasizing that datacenters usually are not solely the spine of contemporary expertise but additionally a pressure for good within the communities they serve. As a part of this dedication, at Microsoft we acknowledge our essential position in defending and replenishing freshwater assets each within the areas the place we function and all over the world.

That’s why in our datacenter operations, one of many important engineering questions we ask every day is: how can we proceed to preserve water whereas assembly rising buyer demand for cloud and AI innovation?

In datacenters, water is primarily used for cooling and humidification. As demand for prime efficiency cloud and AI purposes has grown over the previous few years to gasoline buyer purposes and allow a brand new frontier of discovery and innovation, so have the facility necessities for silicon chips—the fundamental constructing blocks of cloud and AI computing—that sit inside the racks and servers of datacenters. As a result of superior chips sometimes make the most of extra energy, in addition they generate extra warmth. To stop the chips from malfunctioning, extra intensive cooling is required, and this has traditionally required consuming water.

To cut back the water required for operations, a important path to our firm aim of changing into water optimistic by 2030, we’re innovating in all places from our datacenter buildings all the way in which to the chips. Collectively, this work is delivering substantial outcomes. From our first technology of owned datacenters within the early 2000s to our present technology in 2023, we now have lowered our water depth (water consumed per kilowatt-hour) by over 80%. This reveals that it’s doable to considerably cut back how a lot water our datacenters use per kilowatt of energy at the same time as our cloud infrastructure expands.

At the moment, we’re sharing extra about two focus areas for persevering with to drive down water depth: (1) conserving water at each stage of operations, and (2) modern applied sciences that cut back the quantity of water wanted for cooling.

Conserving water at each stage of operations

In any respect areas, we work to attenuate the quantity of water we require for cooling. This consists of working our datacenters at a temperature that permits us to chill with out of doors air the vast majority of the yr, decreasing the necessity for ambient cooling, and conserving water at each stage of day-to-day operations.

diagram
In our datacenters, we work to attenuate the quantity of water we require from municipal water techniques. This consists of water conservation practices in present datacenters and new datacenter designs which might be optimized to assist AI workloads and devour zero water for cooling.​

We conduct common audits of our datacenters to determine inefficiencies and areas the place design and day-to-day use don’t align. Our 2022 audit resulted in focused enhancements that eradicated 90% of the situations by which extra water was used. As well as, we’re constructing superior prediction fashions that assist us anticipate water necessities primarily based on real-time climate and operational information. Evaluating anticipated must precise consumption patterns permits us to rapidly determine inefficiencies, corresponding to water leaks which will in any other case go unnoticed.

To attenuate freshwater necessities from municipal water techniques, we make use of conservation methods which might be tailor-made to the bioregion of the datacenters. For instance, in Texas, Washington, California, and Singapore we’ve expanded our use of reclaimed and recycled water. Within the Netherlands, Eire, and Sweden we’re harvesting rainwater, and we’re additionally bringing this functionality to new datacenters in Canada, the UK, Finland, Italy, South Africa, and Austria.

Progressive applied sciences that cut back the water wanted for cooling

Progressive cooling applied sciences are important to Microsoft’s water technique, and we’re quickly increasing confirmed options throughout our datacenter portfolio. This consists of options that convey cooling on to the supply of warmth technology—the chip itself.

Chilly plates are a major instance of this: a direct-to-chip cooling expertise that gives warmth trade in a closed loop system. Chilly plates dissipate warmth extra successfully than conventional air cooling, immediately chilling the silicon after which recirculating the cooling fluid, like a automobile radiator. This answer considerably improves cooling effectivity and permits extra exact temperature management in comparison with conventional strategies.

To harness the elevated effectivity chilly plates supply, we’re creating a brand new technology of datacenter designs optimized for direct-to-chip cooling, which requires reinventing the structure of servers and racks to accommodate new strategies of thermal administration in addition to energy administration. In present datacenters, we’re additionally utilizing improvements just like the ‘sidekick,’ a liquid cooling system we’re already utilizing adjoining to racks of Microsoft Azure Maia AI Accelerator chips, circulating fluid to attract warmth away from the chilly plates hooked up to the floor of the chips.  

We’re additionally evolving chilly plate applied sciences by way of our work with microfluidics, a expertise that brings cooling contained in the silicon by integrating tiny fluid channels into chip designs. Embedding the liquid cooling contained in the chip brings the coolant proper subsequent to the processors, leading to much more effectivity and precision.

Our latest datacenter designs are optimized to assist AI workloads and devour zero water for cooling. To attain this, we’re transitioning to chip-level cooling options, offering exact temperature cooling solely the place it’s wanted and with out requiring evaporation. With these improvements, we are able to considerably cut back water consumption whereas supporting greater rack capability, enabling extra compute energy per sq. foot inside our datacenters.

Lowering world water use by way of partnership, investing to replenish water

Our water optimistic aim guides us to contemplate not solely how we are able to shift our enterprise practices to cut back our water footprint but additionally how this work can profit clients and companions working towards comparable targets. The 5 pillars of water optimistic: discount, replenishment, entry, innovation, and coverage all play essential roles in our water optimistic journey.

Over the previous yr, we grew our water replenishment program considerably, almost doubling our water replenishment portfolio to incorporate greater than 49 replenishment tasks all over the world. Collectively, these have the potential to replenish greater than 24,000 Olympic dimension swimming swimming pools over the lifetime of the tasks. We additionally met our 2030 water entry goal to supply 1.5 million individuals with entry to scrub water and sanitation companies.2

As well as, we’re working to cut back world water use by collaborating with clients, companions, native communities and municipalities to advance water infrastructure and coverage across the globe. As a result of company approaches to water administration usually lag investments in carbon discount1, we’re taking an energetic position in championing efficient and modern water administration practices and water insurance policies. A few of our advocacy tasks embrace: (1) serving on a coalition to extend water reuse and recycling throughout the USA, (2) funding tasks that assist Tribal Nations and state governments in growing water safety, and (3) supporting analysis, evaluation, and advocacy on water within the European Fee.

Be taught extra about how Microsoft is advancing sustainability

Be taught extra about how we’re advancing sustainability by way of our Sustainable by design weblog collection, beginning with Sustainable by design: Advancing the sustainability of AI. For extra info on our progress in direction of our sustainability targets, learn the Microsoft 2024 Environmental Sustainability Report.